CO-Oximeter Proves A Good Predictor of Fluid Responsiveness in Mechanically Ventilated ICU Patients

By  | February 12, 2018 | Filed under: Float Switch, Level Sensors, Wireless Sensors

A recently published study by researchers at Bülent Ecevit University in Zonguldak, Turkey compared two noninvasive methods of predicting fluid responsiveness in mechanically ventilated patients in the intensive care unit (ICU). They are Masimo PVi (pleth variability index, measured noninvasively and continuously using SET® pulse oximetry sensors) and dIVC (distensibility index of inferior vena cava, measured noninvasively by radiologists using an ultrasound machine and probe). Results show that noninvasively assessed PVi and dIVC were good predictors of fluid responsiveness after PLR in ICU patients on mechanical ventilation. By contrast, the invasively assessed CVP was a poor predictor of fluid responsiveness as a static variable of cardiac preload.

 

In the study, researchers sought to compare the performance of the two methods by enrolling 72 mechanically ventilated patients and taking various measurements before and after passive leg raising (PLR). In addition to PVi (measured with Masimo Radical-7® Pulse CO-Oximeters®) and dIVC (measured by a radiologist using Esaote MyLab 30), central venous pressure (CVP) and cardiac index (CI) were measured. Patients who exhibited a >15% increase in CI attributable to the PLR maneuver were classified as volume responders, and those with <15% or no change, as non-responders.

 

The researchers found that Masimo noninvasive and continuous PVi, at a threshold value of >14%, provided 95% sensitivity and 81.2% specificity (p<0.001, AUC = 0.939 (0.857-0.982)), which was statistically significant. Ultrasound, noninvasive dIVC, at a threshold value of >23.8%, provided 80% sensitivity and 87.5% specificity (p=<0.001, AUC = 0.928 (0.842-0.975)), which was also statistically significant. The invasive method, CVP, at a threshold value of ≤7 mmHg, provided 70% sensitivity and 53.1% specificity to predict fluid responsiveness (p=0.066, Area Under the Curve = 0.622 (0.500-0.724)), which was not statistically significant.

 

The investigators’ results show that noninvasively assessed PVi and dIVC were good predictors of fluid responsiveness after PLR in ICU patients on mechanical ventilation. By contrast, the invasively assessed CVP was a poor predictor of fluid responsiveness as a static variable of cardiac preload.” They concluded that, Both PVi and dIVC may be used to identify the fluid responsiveness of all ICU patients undergoing continuous treatment linked to mechanical ventilation; both methods are easily applied, noninvasive, and can be performed at the bedside.

 

For more info, visit Masimo.

Source Article from http://www.sensorsmag.com/components/co-oximeter-proves-a-good-predictor-fluid-responsiveness-mechanically-ventilated-icu?utm_source=internal&utm_medium=rss
CO-Oximeter Proves A Good Predictor of Fluid Responsiveness in Mechanically Ventilated ICU Patients
http://www.sensorsmag.com/components/co-oximeter-proves-a-good-predictor-fluid-responsiveness-mechanically-ventilated-icu?utm_source=internal&utm_medium=rss
https://www.sensorsmag.com/rss/xml
Sensors Magazine

Sponsored By:

The Deeter Group

Deeter Electronics Ltd. | Deeter Electronics Inc | Deeter Group Asia | Deeter Group Germany | Deeter Group Corporate

Head & Registered Office:
Deeter Electronics Ltd.
Deeter House,
Valley Road,
Hughenden Valley,
Bucks. HP14 4LW

Tel: +44 (0) 1494 566 046
Fax: +44 (0) 1494 563 961
E-mail: [email protected]


The Deeter Group with products ranging from: , , , continuous , 4-20mA , , , , , , , a , wireless sensor and much more.

If you want a standard or a custom level switch, float switch, level sensor, or wireless sensor, contact us via email [email protected] or call us now on 01494 566 046.

Company Name: The Deeter Group

Location: Hughenden Valley, UK

Deeter Electronics USA
Deeter Electronics USA
Wireless sensor system | Radio telemetry | Level switches | Level sensors | Liquid level sensor | Float switches | Controllers & indicators | Industrial weighing equipment | Electronic circuit design & manufacture | Software design | Reed relays | Ultrasonic level flow sludge & proximity sensors | Proximity sensors & switches | Reed switches | Litz wire | Wago Terminals | Mechanical & magnetic floats | Boiler control |

Deeter Electronics UK
Wireless sensor system | Radio telemetry | Level switches | Level sensors | Liquid level sensor | Float switches | Controllers & indicators | Industrial weighing equipment | Electronic circuit design & manufacture | Software design | Reed relays | Ultrasonic level flow sludge & proximity sensors | Proximity sensors & switches | Reed switches | Litz wire | Wago Terminals | Mechanical & magnetic floats | Boiler control |

Deeter Electronics Europe
Wireless sensor system | Radio telemetry | Level switches | Level sensors | Liquid level sensor | Float switches | Controllers & indicators | Industrial weighing equipment | Electronic circuit design & manufacture | Software design | Ultrasonic level flow sludge & proximity sensors | Proximity sensors & switches | Reed switches | Litz wire | Wago Terminals | Mechanical & magnetic floats | Boiler control |

Sensor Magazine Websites
Explosion Proof Sensors UK | Explosion Proof Sensors | Water Level Measurement | Liquid Level Sensing | Liquid Level Measurement | Liquid Level Sensors UK | Liquid Level Sensors Europe | Wireless Sensors | Sensor Magazine | Industrial Sensors